Introduction

We design a digital oscilloscope with STC8A8K chip as the control core, which mainly consists of two modules: hardware circuit and software program. The hardware module mainly includes OLED screen, voltage divider circuit, filter circuit, clock system, power supply and management module and so on. The software module mainly includes ADC sampling, OLED display, interrupt timing and some necessary data processing. its measurable bandwidth is 0-3000Hz, and measured range is 0-30V. After many tests and comparisons, the design achieves the amplification and reduction of waveform and the measurement of different frequency waveform in the experimental process, so as to achieve the desired goal.

Methodology

Design idea

The overall circuit is shown in Figure.1. The core component of this circuit is STC8A8K64S4A12 chip, which is single clock/machine cycle microcontroller produced by STC Co. Ltd. It is a new generation of microcontroller with wide voltage range, high speed, high reliability, low power and super strong anti-interference. Rich digital peripherals and analog peripherals are provided in this microcontroller, including 4 serial ports, 5 timers, 4 sets of PCA, 8 groups of enhanced PWM and I2C, SPI, 16 channels 12 bit ADC and comparator, which can meet almost all the needs of users when designing a product.

For this project, we use the serial port control send and receive a string of characters to/from an encoder, which can ensure serial data transmission between encoder and microcontroller. Also, the enhanced PMW current can light up the OLED, and the display driver IC and display peripheral supporting IC work together on the OLED display and determine its current display state.

In a digital oscilloscope, the analog signal is at the input, after amplification and preliminary filtering, goes to an analog-to-digital converter (ADC) with an external clock. Analog-to-digital conversion takes place by means of sampling.The samples are taken at specific rates and the amplitude of each sample is measured and stored. Intuitively, we know that the accuracy of the digital signal at the output depends upon the number of samples that are taken.The STC microcontroller provide high-accuracy and high-speed ADC which fulfill the requirements of high sampling rate. Using program control, the function of running and stopping ADC sampling and analysing completed sampling data in buffer, displaying and clearing waveform all can be realized.

Furthermore, A 3.7V Li-ion battery supply power to the entire circuit, but we want the operating voltage of microcontroller and SSD display is maintained at 5.0V.To increase the voltage, we connect the Li-ion battery and a booster in series to get a higher output voltage. The physical circuit of booster is shown in Figure.2.

This digital oscilloscope was able to convert the analog input voltage to a digital voltage, write the digital data to the memory, read the digital data from the memory, convert the digital data to analog data, and display the analog data. The signal was returned via a STC microcontroller and displayed on the SSD OLED.

Fig.1 Circuit block diagram
Fig.2 Adjustable Lithium Battery Charging Discharge Integrated Module

Hardware circuit module

The Hardware circuit is mainly divided into following parts and respective function are listed as follows:

Fig.3 Schematic diagram

a. Microcontroller:

b. Booster: Bat-Port input , Bat+port can output 5.0V to charger 3.7V Li-ion battery. The V+Port can output an adjustable voltage

c. Encoder(EC11): These device can generate electrical signal based on the movement of encoder, and we connect its terminal to serial port(P32,P33,P34)of microcontroller. With program control, microcontroller will receive and analyse signal sent from encoder, then we can achieve some basic operation of oscilloscope. All operations are completed by the EC11 Encoder. The input include single click, double click, long press, rotate and rotate while pressing.The details are below:

  • Single Click Encoder: Run/Stop sampling
  • Double Click Encoder: Enter Wave Scroll Mode/Parameter Mode
  • Long Press Encoder: Enter Settings Interface
  • Rotate Encoder: Adjust parameters/Scroll waveform horizontally (only available when sampling stopped)
  • Rotate Encoder While Pressing: Switch between options/Scroll waveform vertically (only available when sampling stopped)
  • Switch Auto and Manual Range: Rotate Encoder clockwise continuous to enter auto range. Rotate Encoder anticlockwise to enter manual range.

d. Bypass capacitors(an electrolytic capacitor 47uF & a ceramic capacitor 10nF):These two paralleling capacitors is at the power pin of microcontroller unit. The propose of this part is to keep the input voltage more stable and filter out the voltage spikes. So it can protect the microcontroller unit when the power on. They can also filter out the low and high frequency noise respectively.

e. Terminal(2 pin): It is an input of digital oscilloscope.

f. Signal light(indicator): Generally, the indicator on means the sampling is running. The more important use is in Single and Normal Trigger Mode, before get into the trigger stage, pre-sampling is required. The indicator will not on during pre-sampling stage. We should not input signal until the indicator comes on. The longer time scale selected, the longer waiting time of pre-sampling.

g. SSD display:

h.

i. Voltage divider circuit(a 1W 11k resistor & a 1/4w 2.2k resistor): which serve to convert an input voltage signal ranging from 0V to +30V to a scaled signal ranging from 0 to +5V.This is done to protect the ADC which requires a unipolar voltage input with a maximum of +5V volts.

Software program module

Experimental setup

Step 1:Preparation

In the project, we will make a simple oscilloscope. STC8A8K64S4A12 chip has fast calculation speed, comes with ADC module and has large RAM space for sampling and OLED screen cache. In addition, AGND, AVREF, AVCC pins can improve the accuracy of sampling. So, STC8A8K64S4A12 chip was decided to be our important microcontroller module. The design idea of the circuit diagram has been clarified in previous.

Material List:

  • MCU: STC8A8K64S4A12(core component)
  • Display: SSD OLED with 7-Pin SPI Interface
  • Resistor:1W 11k&1/4W 2.2k(for voltage division), 1/4W 11k(for current limiting) ,5k
  • Capacitor:47uF, 0.01uF(for wave filtering)
  • EC11 Encoder(for controlling of oscilloscope),Toggle Switch(for power switch),2-Pin Terminal(for input of oscilloscope),LED
  • IC Socket 40-Pin,Row Pin(for installation of OLED display and programming the MCU)
  • 3.7V Li-ion Battery(power source)
  • 5V Booster Module(power module with Li-ion charging management and boost function)
  • USB-TTL Downloader(for downloading program to MCU)
  • Circuit Board

Step 2:PCB board design and layout

PCB was deawn according to the schematic using Altium Designer. Package specifications were based on the package library provided by the software offical and other few drawn by ourselves.

Fig.4 PCB design (Double-side circuit)

Step 3:Circuit soldering

The circuit was welted using a 350 degree soldering iron and solder according to the circuit schematic.

Fig.5 Actual soldered circuit

Each interface was tested for ohms and the pin contact was good and in line with the theoretical values. Therefore, the circuit was found to be well built.

Step 4:Programming and downloading the code to microcontroller

Fig.6 Interface of STC-ISP for program downloading
Fig.7 Usb serial port for communication

Connect the TXD and RXD terminals of the MCU and complete the program download by connecting to the computer via USB. The code is written in C and converted to .hex and .bin files for writing to the chip. Once the program file and EEPROM file are configured, the program can be downloaded. For the STC we use, a cold boot is required to download the program using the boot sector.

During the actual operation, unexpectedly, our program could not be downloaded.

Step 5:Test and measurement

Discussion

In this experiment, although there were no problems with the experimental steps, problems arose during the writing downloading phase. The main reason for choosing this chip was its ADC function and online burning function. After checking, we found that many engineers had encountered many problems during the writing downloading process.

The first situation is the failure of writing downloading through the USB to serial port. The reason for this is that for some chips, a dedicated chip USB to serial port is required. The second situation is that sometimes some chips in the same batch can be programmed online, while others cannot. It may be that there are minor package differences that cause problems with this writing downloading process.

There are also problems with jumping when using the chip, and sometimes the light flickers. Using direct battery power did not improve the problem, so we also ruled out a DC-DC effect. We suspected that there might also be a problem with the chip itself. We also found that this jumping problem is related to the quality of each microcontroller.

Future improvement can be done

  • One of the biggest design problem of this oscilloscope is the inability to measure negative voltages. Since the oscilloscope measures voltages in the range 0 V to 27 V, a shift can be made using an isotropic adder. Choose suitable resistors and capacitors in the schematic and add the adder to input part. The calculation formula is as follows.


Fig.8 Amplification circuit for improvement
  • Use a higher performance microcontroller, such as the STM32, and reduce the problems with writing downloading and jumping.
  • Consider accelerating the external ADC to increase the speed and add a cache mechanism.
  • Use a colour screen or two OLEDs, one for waveform display and one for parameter display.


Throughout the project, we learned a lot more than just how to build a breadboard digital oscilloscope. We learned how to design a breadboard digital oscilloscope. We did everything from reading and interpreting data sheets to trouble programming errors. By successfully completing these tasks and producing the functional breadboard digital oscilloscope we were able to demonstrate fundamental levels of understanding in basic electronic techniques, digital electronics, data acquisition, and data analysis.