Schlieren Imaging

From PC5214 wiki
Jump to navigation Jump to search

Idea

Schlieren Imaging is a technique proposed by the German physicist August Toepler in 1864 to study supersonic motion. We are using this tool to see the ultrasound wave and its propagation. The sound wave is propagation by the vibration of the air. When the air vibrates, the air will be either denser or less.

Setup

Version 1

The optical setup is shown below.

Experimental Setup

The light source is a high-power LED that drives at about 3V 3A. There is an aperture in front of the led to block most of the light and make the source a point source. A concave mirror is located at 2f from the source. The concave mirror has a small angle to the instance beam. So the reflected light will go beside. There is a knife-edge at the reflection path about 2f from the concave mirror. Its function is to block half of the beam. A camera is located behind the knife edge to view the image.

The picture of the real setup looks like below. The concave mirror is on the left hand of the picture while the camera, knife-edge, and the source are on the right-hand side.

Whole real setup

The source and the knife-edge are clearly shown below. A black cover is used to block the stray light so that it will not influence the imaging process as the light from the aperture is relatively too weak. There is a bright blue dot projected on the knife edge. That is half art of the minimum waist radius of the beam. So when the air density changes, the sharp pattern will move up and down and cause the image brighter or darker.

source setup

One thing that needs to be careful is not to let the knife-edge/camera be too far from the point source. Otherwise, the smallest wrist will not be round enough. It will come elliptically when the instance beam and the reflected beam are not overlapped very well. The elliptical shape of the beam can harm the resolution of the device.

Version 2

Measurements

....